Coliy  Group

sales@coliy.com   
HOME PRODUCTS ABOUT US NEWS CONTACT
HOME PRODUCTS ABOUT US NEWS CONTACT

Home > Products > Weak magnetic field meter
GF603 3-Axis Fluxgate Magnetometer

• Range: ±1G(±100μT) and ±10G(±1mT)
• DC Basic Accuracy: 0.25%
• Frequency response of DC- 1kHz
• S or N Polar indication
• Max/Min/Hold Function
• Display XYZ components and vector
• Display Resultant (R), Declination (D) and Inclination (I)

Download


COLIY®--Excellent Solution for Magnetic  Field Measurement

High Magnetic Field (0-20T) Measurement

Model

Principle

Type

Axis

DC Accuracy

Range

Resolution

G80

HALL

Handheld

1

2%

2T

10μT

G81

HALL

Handheld

1

0.8%

10T

1μT

G93

HALL

Handheld

3

1%, 0.5%

20T

10μT

G401

HALL

Desktop

1

0.04%

10T

1μT

X113

HALL

Sensor

1

0.05%

15T

TC of sensitivity: 30ppm/K

Low Magnetic Field(0- 2mT) Measurement

Gaussmeters for Low Magnetic Field

Model

Principle

Type

Axis

DC Accuracy

Range

Resolution

GF601

Fluxgate

Handheld

1

0.5%

1mT

0.1nT

GF603

Fluxgate

Handheld

3

0.25%

1mT

0.1nT

Note: 1T= 10kG; 1mT= 10G;  1μT= 10mG;   1nT= 10μG


GF603 Three-Axis Fluxgate Magnetometer



Description: 

Three-axis Fluxgate Magnetometer GF603, made by COLIY, has the excellent ergonomic design with the latest electronic technology, and it’s one of best choices to measure low-intensity magnetic field. This handheld fluxgate magnetometer can be used in geomagnetism detection, wrapped detection, traffic monitoring, measuring residual magnetism, low-intensity magnetic field measurement, etc.

GF603 boasts with an industrial class 3.2 inches touch panel display that enables customers’ instantaneous and simultaneous measurement results [Max/ Min/ Peak/ Hold/ Alarm/ Polarity, XYZ axis and vector of Magnetic Flux Density, Declination/Inclination (D/I), Trend Graph and Real-time Spectrum Analysis (with model GF603S) etc.].

Magnetometer GF603 can be used to detect DC magnetic field in DC measurement mode and AC magnetic field in AC measurement mode respectively: GF603 allows DC measurements with a basic accuracy of 0.25%, resolution of 0.1nT and AC measurement with a basic accuracy of 1% and frequency response range of DC~ 1kHz. Magnetometer GF603 could be equipped with 3-Axis Probes of different range: ±100μT and ±1000μT. Meanwhile, Magnetometer GF603S has the function of real-time spectrum analysis within the frequency range 15Hz- 1kHz.

In addition, Magnetometer GF603 has passed the CE certification and EMC (Electromagnetic Compatibility) test.



Features

GUI Operation System

3.2 inches color touch LCD

Full 5 display digits

Max/Min/Hold Function

Display trend graph & Alarm

Display XYZ axis and vector

Display R, D, I values

S or N Polar indication

Range: ±100μT and ±1000μT

DC Basic Accuracy: 0.25%

AC Basic Accuracy: 1%

Finest resolution: 0.1nT

DC/AC measurement mode switch

Frequency response: DC- 1kHz

Smart record and review

[GF603S] Real-time spectrum analysis



GUI Operation System

 

With the handheld instrument operating system (GUI Operation System) developed by COLIY, it’s very efficient and convenient for operators to choose menu by touching, to operate magnetometer.

Display Style

 

Color LCD shows magnificent data: time, value, polarity, Max, Min, note, Alarm, XYZ axis and vector of Magnetic Flux Density, Declination/Inclination (D/I), and trend graph.

Smart Record and Review

 

Detailed record list, operators can use MEMO to memorize any specification of every measurement.

Click any record list, operators can review all the information recorded as screen shots and add note to every item.


                                      XYZ Display Mode

 

GF603 has many display modes to be chosen: Standard Mode, XYZ Mode, D/I Mode, Graph Mode, Polarity Mode and Spectrum Mode.

And XYZ Mode shows vector value, XYZ component values and alarm value.

                  D/I Display Mode

 

Declination is the angle that between the X axis and the projection of the field vector onto the XY plane. Inclination is the angle that between the field vector and the XY plane.

And D/I Mode shows Resultant (vector value, R), Declination (D) and Inclination (I) values.

                              Real-time Spectrum Analysis

 

GF603S has the function of real-time spectrum analysis within the frequency range 15Hz- 1kHz.

                AC Measurement Mode

 

GF603 can be used to detect DC magnetic field in DC measurement mode and AC magnetic field in AC measurement mode respectively, and the frequency response range is DC~ 1kHz.

                                  Magnetic Pole DIirection

 

GF603 could show the clear polar indication by a colorful and dynamic cartoon picture. Picture in the left is adopted from Polar Mode displayed in the LCD screen during operation. 

3D Movement Platform

 

3-Direction Precision Movement Platform, is made of non-magnetic material. Users fixed the probe on the bracket front-end, and then manually rotate the knob so that the probe moves stably along the X, Y, Z-axis to a certain position and lock fixed. Maximum stroke of each axis is 150mm, and positioning accuracy is 0.1mm.


SMART PC Software 

SMART computer software has up to 7 digital readouts, and it has rich features: Automatically record and display trend graph; Display XYZ axis and vector of magnetic flux density, maximum and minimum in real time; Export saved data from the gaussmeter host; Record and save measurement data in real time.


GF603 Magnetometer Specification:


Model

GF603 / GF603S

(DC) Measurement Specification

Tested item

X, Y, Z

Vector R

*D

*I

Range (FS)

±100μT

±1000μT

173μT

1732μT

±180°

±90°

Accuracy

±0.25% Reading   ±  0.1% FS

±0.25% Reading   ±  0.1% FS

±0.5% Reading   ±  0.1% FS

±0.5% Reading   ±  0.1% FS

Finest Display Resolution

0.1nT

0.1nT

0.1°

0.1°

Measurement Resolution

<1nT

<10nT

<1nT

<10nT

0.1°

0.1°

[Probes without Temp. Compensation] Typical Temperature Coefficient ppm/

±100

±200

±100

±200

N/A

[Probes with Temp. Compensation] Typical Temperature Coefficient ppm/

±25

±50

±25

±50

N/A

Display Digits

5 digits (More display digits will be shown in supporting PC software)

4 digits

Real-time Spectrum

Only GF603S

N/A

Hysteresis

<2nT for exposure to up to 2 x full scale

N/A

(AC) Measurement Specification

*Range

X, Y, Z

±70μT

±700μT

R

121.2μT

1212.4μT

Accuracy

X, Y, Z

±1% Reading ± 0.1% FS   [fT ≤ 300Hz]

±2% Reading ± 0.1% FS   [300Hz < fT ≤ 500Hz]

±10% Reading ± 0.1% FS  [500Hz < fT  ≤ 1000Hz]

R

±2% Reading ± 0.1% FS   [fT ≤ 300Hz]

±4% Reading ± 0.1% FS   [300Hz < fT ≤ 500Hz]

±18% Reading ± 0.1% FS  [500Hz < fT  ≤ 1000Hz]

Frequency Response [fT]

DC – 1kHz

Front Panel

Screen

3.2 inches color resistive touch LCD,320x240 Pixel

Units

Gauss(G), Tesla(T), Amperes per meter (A/m)

Display Update Rate

3 readings/second

Display Mode

DC, AC, XYZ Axis, Vector R, Declination, Inclination, MAX, MIN, Trend Graph, Alarm, Polarity Indication, Real-time Spectrum [GF603S] etc.

Probe

Start-up Time

150 ms

Warm-up Time

15 min

Probes

See "Probe Specifications" for details.

Probe Cable Length

Standard 1.5m; Customizable longest length of 30 m

USB Interface

Function

1, Communication Interface: to connect PC with gaussmeter host for monitoring the measurement;

2, Charging interface: to connect PC or mobile power with gaussmeter host for charging

Software/ Driver

SMART PC Software without any driver

Host Specifications

Operating Temperature

+15  to  +35(Rated Accuracy)

-10  to  +60(Reduced accuracy)

Storage Temperature

- 20°C  to  +75°C

Ambient Magnetic Field

<100G (10mT)

Battery

Rechargeable 4500mAH Li-ion

Operating Battery Life

5 hours; Can be charged by AC power or portable battery

Dimension

238 mm W × 95 mm H × 42 mm D

Weight

350g

Certification

CE Certification, EMC Certification

Note:

1, D- Declination, is the angle that between the X axis and the projection of the field vector onto the XY plane.

2, I- Inclination, is the angle that between the field vector and the XY plane.

3, AC Range mentioned above refers to AC magnetic field measurement range after DC magnetic field is shielded, so if DC magnetic field is not shielded, and users want to measure magnetic field in AC measurement mode, AC Range is equivalent to the value that 0.7 times of DC Range minus DC magnetic field intensity. [SQRT(2)/2 ≈ 0.7]

Probes Specification

Model GF603 Magnetometer Probes

Probe Model

*Range

Frequency

Response

Typical

Temperature Coefficient

DC Accuracy

( 25℃)

Stem Material

GF-Y01

±100μT

DC-1kHz

±100ppm/℃

±0.25%

POM

GF-Y01T

±100μT

DC-1kHz

±25ppm/℃

±0.25%

POM

GF-Y10

±1,000μT

DC-1kHz

±200ppm/℃

±0.25%

POM

GF-Y10T

±1,000μT

DC-1kHz

±50ppm/℃

±0.25%

POM

Note:

1, Three-axis fluxgate probe can be customized within ±10G; Unit Conversion: 1G=100,000nT;

2, Fluxgate probe’s dimension: 107 x 32 x 32mm, and its operating temperature: -20℃ to +60℃;

3, Fluxgate probe’s environmental protection / sealing is IP66 by default;

4, Please contact Coliy for probes with higher environmental protection,  the fluxgate probe in the long-term work of 50 meters underwater.

Optional Accessories


Model

Descriptions

GHOLD100

3-Direction Precision Movement Platform, is made of non-magnetic material. Users fixed the probe on the bracket front-end, and then manually rotate the knob so that the probe moves stably along the X, Y, Z-axis to a certain position and lock fixed. Maximum stroke of each axis is 150mm, positioning accuracy of 0.1mm; center load: 10kg; weight: 3.5kg

SAMRT PC Software

PC SOFTWARE for Magnetometer

Probe Extension Cable

MAX length is 30m


The most popular configuration

Package Product No. GF60301: Magnetometer GF603 + Probe GF-Y01

Package Product No. GF60310: Magnetometer GF603 + Probe GF-Y10

Package Product No. GF603S01: Magnetometer GF603S + Probe GF-Y01

Package Product No. GF603S10: Magnetometer GF603S + Probe GF-Y10


Description of Magnetometer Host Type Selection


Magnetometer

Description

GF603

Magnetometer WITHOUT the function of real-time spectrum analysis

GF603S

Magnetometer WITH the function of real-time spectrum analysis

Description of Probe Type Selection


GF

Y

01

T

PROBE PRINCIPLE

 


GF- Fluxgate Probe

 

           PROBE TYPE

 


Y- Three-axis Probe

T- Transverse Probe

A- Axial Probe

       MEASUREMENT

             RANGE

 

01- Range of 1G/Axis

10- Range of 10G/Axis

   TEMPERATURE 

  COMPENSATION

 

BLANK- Without

T- With




Feedback Please submit your comments, we will give you the first time feedback!

Title: *
Name: * E-mail:* Tel:*
Content:*
Code: 
*

COPYRIGHT ©  2022 Coliy  Group  

Support:35.com
Follow Us :